A wrongly wired sensor or an untested PLC change can stop an entire line. A skipped energy isolation puts lives at risk. AHİMARK assesses automation specialist candidates on the topics a maintenance or automation lead would raise in a first technical interview: can they read a schematic and match it to the field, do they change and test a PLC program safely, and do they find faults methodically?

What we measure

The framework was developed under expert supervision and consists of 7 areas, 60 sub-competencies and 546 indicators. It runs from the panel to the field, from the PLC to communication and commissioning. Environments and protocols common on the shop floor, such as TIA Portal, PROFINET, Modbus, IO-Link and HART, are also covered. Documentation is an area of its own: recording a change made in the field in the schematics, the as-built records and the project backup matters as much as wiring it correctly.

  • Work Organization and Management
  • Occupational Health and Safety
  • Schematics and Technical Documentation
  • Control Panel and Field Hardware
  • PLC Configuration, Programming and Control
  • Industrial Communication
  • Commissioning, Maintenance and Repair

One area up close: from indicator to assessment tool

Every line of the report rests on an indicator. The example area is Control Panel and Field Hardware: a measurement taken the wrong way in the panel or in the field puts people and equipment at risk, and commissioning without checking that the field signal reaches the PLC correctly lets the fault appear while the machine is running. Knowledge indicators are measured by the interview and the test, skill indicators by the simulation.

Competency areaSub-competencyIndicatorAssessment toolExample question or task
Control Panel and Field HardwareElectrical Measurement Methods and PracticeExplains the reasons for checking the suitability of the meter and probes, for verifying the absence of voltage, and for checking that the meter works before and after the task.OTO.D.7.X2InterviewTestInterview: You are going to replace a contactor coil in the panel. How do you verify there is no voltage, and why do you test the meter on a known source before and after?
Control Panel and Field HardwareElectrical Measurement Methods and PracticePerforms voltage, current or continuity measurements within their own task and authority limits, using the approved method.OTO.D.7.Y3SimulationSimulation (panel): The candidate takes measurements on the faulty circuit. The simulation records whether the approved method was followed; a resistance measurement on a live circuit is not accepted.
Control Panel and Field HardwareVerifying I/O Signals and Control LoopsMatches digital input and output states with the given control scenario and reference states.OTO.D.8.X1InterviewTestTest: On the conveyor a part sits in front of the sensor and the sensor light is on, but the PLC input reads 0. What is the first suspect? Correct answer: the sensor type (PNP/NPN) or its wiring does not match the input card.
Control Panel and Field HardwareVerifying I/O Signals and Control LoopsTriggers digital inputs according to the given test scenario and compares field states with the PLC input states.OTO.D.8.Y1SimulationSimulation (sorting line): Using an I/O test, the candidate compares each digital input with its field state and finds the sensor of the wrong type.

The simulation applies when the position includes it. The other areas follow the same structure: each indicator is measured either by the interview and the test or by the simulation, and what cannot be measured is left to on-the-job observation in the report.

At which level?

  • L1 Automation Installation and Implementation: Carries out panel assembly and wiring, sensor and actuator installation, PLC programming and monitoring, HMI/SCADA and drive configuration, commissioning tests and troubleshooting.
  • L2 Automation Design and Solution Development: Selects and sizes electrical equipment, designs modular and reusable PLC software and sets up HMI/SCADA data connections. Runs the verification and acceptance tests of safety functions.

You choose the level in your job posting; the interview and test are prepared for that level.

What is discussed in the interview?

Candidates talk about their own experience; without experience, they reason through a realistic situation. Example topics: energy isolation and controlled re-energization before maintenance, verifying an I/O signal from the field to the PLC, testing and backing up a change to a PLC program, locating the fault when communication drops, and checking the safety circuit during commissioning.

What the report shows

A Competency Index out of 10, a score for each competency area and the source behind it; strengths and areas to develop, backed by the candidate's own words. Areas without enough evidence carry an "observe on the job" note, and critical safety weaknesses are flagged separately. The decision is always yours; the system never rejects a candidate automatically.

For example, under PLC Configuration, Programming and Control, how the candidate tests and backs up a program change appears next to the score, in their own words.

FAQ

Is a specific PLC brand assessed?

No. TIA Portal appears in the framework as an example environment; the skills measured (configuration, LAD/FBD/SCL programming, diagnostics, backup, PID control) are brand-independent. The interview follows the environment the candidate has worked with.

Why are there two levels?

The framework separates installation and implementation work from design and solution development. You choose one in your job posting, depending on the job.

How are electrical and machine safety assessed?

The Occupational Health and Safety area covers energy isolation, machine guarding systems and functional safety principles; critical weaknesses in this area are flagged separately in the report. The report does not replace a legal authorization.

What does the candidate complete?

An intake form, a short voice interview and a job test. The candidate can complete them all in one go on their phone; a phone with a microphone is enough.